Max. current : 100A
Pole : 2P 4P
Rated voltage : 1000V-1500V
Rated current : 63A 100A
Product name : Dual Power Automatic Transfer Switch ATS
Color : white
Frequency : AC 50 Hz/60Hz
Operation type : Manual Operation,Auto&Manual
Standard : IEC60947-6-1
Arc extinguishing method : Magnetic blower circuit breaker
FMQ3G-F (PC class) Excitation double power automatic transfer switch
Product Overview
Control device: ICD LCD controller
Product structure: small size, high current, simple structure, ATS-body
Features: fast switching speed, low failure rate, easy maintenance, reliable performance (with automatic switching time adjustable.ls-99s) Wiring: wiring before the board (63, 125, 250, 630),
After the board wiring (800, 1250, 2000, 2500, 3200)
Switching mode: grid to grid, grid to generator, self-injection self-repeating, self-injection non-self-repeating, mutual standby
Products: 63, 125, 250, 630, 800, 1250, 2000, 2500
400, 500, 630, 800, 1000, 1250, 16002000, 2500A
Product classification: two-stage without double disconnect position, three-stage with intermediate double disconnect position
Number of poles: 2, 3, 4
Product standard: GB/T14048.11
ATS level: PC level
Technical requirements
♦In automatic gear, when the common power supply is under voltage, over voltage, loss of voltage, switch to standby power; when the standby power supply has the same fault, switch to double points position, the display shows automatic and alarm at the same time.
The LCD screen protects 30s, display screen when button is pressed for the first time, the second time can enter the setting, enter the setting need password input.
♦When the manual setting is messy (dead), there is a reset key to reset to the default value.
♦When the controller is set in automatic and manual position, the display shows double points when pressing the double points button on the controller panel, but no alarm.
♦the controller is set to delay the time of switching, when the power supply is back to normal within the set value, the double power supply is not switched.
Rated working voltage Ue | AC400V | ||||||||
Rated insulation voltage Ui | 690V | ||||||||
Rated impulse voltage Uimp | 6kV | 6kV | 8kV | 6kV | 8kV | 8kV | 8kV | 8kV | |
Rated limiting short-circuit current lq | / | / | / | 50kV | 65kV | 65kV | 65kV | 65kV | |
Rated short-circuit turn-on capacity Icm | 7.65kV | 17kV | 17kV | / | / | / | / | / | |
Service life (times) | Mechanical | 4500 | 5000 | 5000 | 2000 | 2500 | 2500 | 2500 | 2500 |
Electrical | 1500 | 1000 | 1000 | 1000 | 500 | 500 | 500 | 500 | |
Number of poles | 2 | ||||||||
3 | |||||||||
4 | |||||||||
Operation cycle (sec/time) | 30S | 60S | |||||||
Switching time | 0-99S |
![]() |